Loop Flushing Spool - Danfoss H1B 060 Service Manual

H1 bent axis motors
Hide thumbs Also See for H1B 060:
Table of Contents

Advertisement

Service Manual
H1 Bent Axis Motors, Size 060/080/110/160/210/250 cm3
Minor repair

Loop flushing spool

Loop flushing reassembly
24 mm
K0030
67 N•m [49 lbf•ft]
K0020
K0030A
©
Danfoss | August 2018
Removal
1. Remove plugs (K0030) using a 24 mm hex wrench.
2. Remove and discard O-rings (K0030A).
3. Use a magnet to remove springs (K0020) and spool (K0010).
Inspection
Clean and inspect spool (K0010). If spool is damaged or worn replace it. Replace springs if they are
cracked or bent.
Reassembly
K0010
1. Lubricate and install spool (K0010).
2. Lubricate and install springs (K0020).
3. Lubricate and install new O-rings (K0030A).
4. Install plugs (K0030) using a 24 mm hex wrench with torque to 67 N•m [49 lbf•ft].
K0030
24 mm
67 N•m
[49 lbf•ft]
K0020
K0030A
AX00000025en-US0504 | 63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H1b 080H1b 160H1b 210H1b 250H1b 110

Table of Contents