Neutral Switch Inspection - Suzuki DF70A Service Manual

Four stroke
Hide thumbs Also See for DF70A:
Table of Contents

Advertisement

1I-14 Starting System:
2) Check continuity between terminal (2) and (3) each
time 12 V power supply is applied to terminal (4) and
(5).
Connect the positive (+) lead to terminal (5), and
negative (–) lead to terminal (4).
CAUTION
Be careful not to touch 12 V power supply
wires to each other or with other terminals.
Special tool
(A): 09930–99320 (Digital tester)
Tester knob indication
Continuity (
)
Starter motor relay function
12 V power applied
12 V power not applied
2
5
12 V
4
3) Measure the resistance between relay terminals (4)
and (5).
If out of specification, replace starter motor relay.
Tester knob indication
Resistance (Ω)
Starter motor relay solenoid coil resistance
Standard: 145 – 190 Ω
(A)
Continuity
Yes
No
3
CONT
(A)
I9J011190043-03
I9J011190044-02

Neutral Switch Inspection

Check for continuity / infinity of the neutral switch.
Special tool
(A): 09930–99320 (Digital tester)
Tester knob indication
Continuity (
)
Neutral switch in remo-con box
1) Disconnect the neutral switch lead wire connector
from the ignition switch.
2) Check continuity / infinity between the switch brown
wire leads while operating the remo-con handle.
If out of specification, replace the neutral switch.
Neutral switch function
Shift position
Neutral
Forward
Reverse
(A)
"Reverse"
Br
Br
Z9J0111906008
Tester indicates
Continuity
Infinity
Infinity
"Forward"
I9J011190045-03