Eaton Power Xpert C445 User Manual page 364

Global motor management relay
Hide thumbs Also See for Power Xpert C445:
Table of Contents

Advertisement

Appendix D—Modbus Register Map
Table 128. C445 Modbus Register Map, continued
Register
Name
903
Rated Voltage
904
Rated Frequency
905
Rated Watts Motor1
907
Rated Watts Motor2
909
Rated HP Motor1 Scaled
911
Rated HP Motor2 Scaled
350
Power Xpert C445 Global Motor Management Relay MN042003EN—January 2019 www.eaton.com
Attribute
Description
The rated voltage of the motor from the motor nameplate.
UINT16 RW NV
Default: 480
Range: 100 to 5000
Units: V
Config CRC
Run Lock
Admin Lock
USB Lock
Backup Mem
UINT16 RW NV
Motor Rated Frequency in Hz from the motor nameplate.
Default: 60
Range: 50 to 60
Units: Hz
Config CRC
Run Lock
Admin Lock
USB Lock
Backup Mem
UINT32 RW NV
Watts nameplate rating for motor winding#1 (Used in all control profiles).
Motors will either have a Watts or HP rating on the nameplate. When
Default: 14914 (RW)
Watts is entered for Motor1 the Motor Rated HP will be calculated and
Range: 10 to 3728500
displayed for Motor1.
Units: W
Config CRC
Run Lock
Admin Lock
USB Lock
Backup Mem
UINT32 RW NV
Watts nameplate rating for motor winding#2 (Used in star/delta, two
speed and dahlander profiles). Motors will either have a Watts or HP
Default: 14914 (RW)
rating on the nameplate. When Watts is entered for Motor2 the Motor
Range: 10 to 3728500
Rated HP will be calculated and displayed for Motor2.
Units: W
Config CRC
Run Lock
Admin Lock
USB Lock
Backup Mem
UINT32 RW NV
HP nameplate rating for motor winding #1 (Used in all control profiles).
Motors will either have a Watts or HP rating on the nameplate. When HP
Default: 2000 (RW)
is entered for Motor1 the Motor Rated Watts will be calculated and
Range: 1 to 500000
displayed for Motor1. This value is scaled by 0.01. For example if the
Units: HPx100
motor is rated at 123.25 HP then this parameter should contain 12325.
Config CRC
Run Lock
Admin Lock
USB Lock
Backup Mem
UINT32 RW NV
HP nameplate rating for motor winding #2 (used in star/delta, two speed
and dahlander profiles). Motors will either have a Watts or HP rating on
Default: 2000
the nameplate. When HP is entered for Motor2 the Motor Rated Watts
Range: 1 to 500000
will be calculated and displayed for Motor2. This value is scaled by 0.01.
Units: HPx100
For example if the motor is rated at 123.25 HP then this parameter should
Config CRC
contain 12325.
Run Lock
Admin Lock
USB Lock
Backup Mem

Advertisement

Table of Contents
loading

Table of Contents