Check the conditions of the needle and its hous-
ing (A).
Check chamber O-Ring conditions.
REMOVE THE IDLE SCREW AND IDLING ADJUST-
ING SCREW
- Turn the idle screw (1) clockwise, counting the number
of turns until stop.
This operation allows it to be replaced in the same
regulation position when reassembled.
- Turn the screw (2) clockwise, counting the number of
turns until stop.
This operation allows it to be replaced in the same
regulation position when reassembled.
- Clean the carburettor and parts with specific solvents.
- Spray all carburettor body ducts and its jets with com-
pressed air.
Do not use metallic tools which could ruin ducts
or some elements.