Overland Storage ARCvault Series Service Manual page 39

Autoloader/library
Hide thumbs Also See for ARCvault Series:
Table of Contents

Advertisement

FSC
Message
305f
"Invalid bin number"
3060 "Cart blocking vertical"
3061 "Unable to Complete Homing
Algorithm"
3074
"Drive Eject Failed"
3075 "Drive Eject Failed"
3078 "Diag get drive status failed"
3079 "Diag get drive status failed"
3082 "Drive Stow Fail, Media Returned to
Source"
3083 "Drive Stow Fail, Media Remains in
Drive"
3084 "Unsupported Drive for Requested
Operation"
308F
"No Retry Fault on Fetch/Stow"
30b0 "Mail Slot Load/Unload Error"
3100
"Picker Jammed"
3101
"Picker Overtraveled Stall"
3102
"Flex cable failure"
3115
"Picker Retraction Jam"
3200 "Shuttle Jammed"
3305 "Cart sense switch failed"
10400025-101 10/2006
Table 3-1: FSC/ERP Cross-Reference
ERP Description
1
During cartridge cycle or drive cycle diagnostics,
the library firmware detected an invalid slot
selection. This condition indicates a diagnostic
firmware error.
6
The library detected an unexpected cartridge
ejected from the drive when the shuttle is not in
front of the drive. This condition prevents the
vertical robotics movement and requires manual
intervention.
6
The library could not complete the vertical homing
algorithm. This usually indicates an obstruction
(such as, a cartridge in the bottom of the chassis or
other impediment).
7
The library issued an eject command over the ADI
and drive 1 did not successfully eject.
7
The library issued an eject command over the ADI
and drive 2 did not successfully eject.
2
The library diagnostic firmware failed to get ADI
status from drive 1.
2
The library diagnostic firmware failed to get ADI
status from drive 2.
7
The library was unable to successfully stow a
cartridge to the drive so the cartridge was returned
to the originating slot.
7
The library was unable to successfully stow a
cartridge to the drive but the cartridge was left in
the drive.
2
The library detected an unsupported drive (usually
a hardware error).
1
A robotics fetch stow operation failed and no retry
was possible.
6
The library was unable to fetch/stow the import/
export slot.
7
The library detected a jam condition with the picker
motor.
7
The library detected an unexpected overtravel
condition when moving the picker motor to a
position (stall was expected).
1
The library was unable to extend the picker due to a
possible flex cable fracture.
7
The library was unable to retract the picker motor
and a jam condition was detected.
7
The library shuttle motor was stalled/jammed
during a shuttle move operation.
6
The library did not detect the cartridge sense
switch in the shuttle assembly.
Troubleshooting and FSCs
3– 5

Advertisement

Table of Contents
loading

Table of Contents