Temperature, Humidity And Altitude; Shock - Overland Storage ARCvault Series Service Manual

Autoloader/library
Hide thumbs Also See for ARCvault Series:
Table of Contents

Advertisement

1.5.4 Temperature, Humidity and Altitude

Operating
Dry Bulb Temperature
Temperature Gradient
Temperature Shock
Wet Bulb Temperature
Relative Humidity
Humidity Gradient
Power On—No Tape Loaded (Unpacked—72 hours)
Dry Bulb Temperature
Temperature Gradient
Temperature Shock
Wet Bulb Temperature
Relative Humidity
Humidity Gradient
Non-Operating—Long Term (Packed or Unpacked)
Dry Bulb Temperature
Temperature Gradient
Temperature Shock
Wet Bulb Temperature
Relative Humidity
Humidity Gradient
Transit—Short Term (Packed 7 Days)
Dry Bulb Temperature
Temperature Gradient
Temperature Shock
Wet Bulb Temperature
Relative Humidity
Humidity Gradient

1.5.5 Shock

Operating (Within Spec—No Damage)
Peak Acceleration
Duration
Wave Shape
Application
Non-Operating, with Tape Cartridges Removed (Unpacked—No Damage)
Peak Acceleration
Duration
Wave Shape
10400025-101 10/2006
-10°C to 40°C
1°C / min. (across the range)
15°C (over 2 min.)
26°C
15% to 85% (noncondensing)
10% / hr.
0°C to 50°C
15°C / hr. (across the range)
15°C (over 2 min.)
30°C
10% to 95% (noncondensing)
10% / hr.
-40°C to 60°C
20°C / hr. (across the range)
15°C (over 2 min.)
30°C
5% to 95% (noncondensing)
10% / hr.
-40°C to 60°C
25°C / hr. (across the range)
15°C (over 2 min.)
30°C
5% to 95% (noncondensing)
10% / hr.
31 Gs ±5%
2.6ms
1/2 sine pulses
X,Y,Z axes
71 Gs ±5%
2ms
1/2 sine pulses
General Information
1– 5

Advertisement

Table of Contents
loading