Table 3-1: Fsc/Erp Cross-Reference - Overland Storage ARCvault Series Service Manual

Autoloader/library
Hide thumbs Also See for ARCvault Series:
Table of Contents

Advertisement

FSC
Message
101
"Serial Port Initialization Error"
306
"NVRAM Update Error"
402
"Non-Volatile Configuration Save
Error"
404
"Drive Configuration Error Full-
height drive Is incorrectly cabled."
405
"Drive Initialization Error"
501
"Bar Code Reader Not Detected"
901
"OS Critical Error"
902
"Network Catastrophic Error"
0A01
"Invalid Ethernet (MAC) Address"
0A02 "Invalid IP Subnet Mask
(255.255.255.255)"
0C01 "Exception Error" or
"Firmware Exception"
1001
"SCSI Firmware Error"
1011
"SCSI Initialization Error.
None of the attached drives have
ADI Bridging Enabled."
2001 "Invalid Control Command"
2004 "Loader Not Ready"
2008 "Illegal Move"
2009 "Door Open"
200F
"Drive Media Removal Prevented"
2010
"Control Firmware Error"
20b0 "Unknown exchange for the async
message"
3000 "Motor Fault Condition, see trace
for details"
10400025-101 10/2006

Table 3-1: FSC/ERP Cross-Reference

ERP Description
1
The serial port controller on the library controller
card failed to initialize during POST.
1
The Non-Volatile RAM did not update during POST.
1
The Non-Volatile RAM configuration did not save
correctly during POST.
2
The library detected that the wrong serial cable is
connected to the full height drive.
2
The tape drive did not initialize correctly during
POST.
1
The bar code reader was not detected during POST.
1
The library firmware encountered a critical internal
error.
1
The RMU firmware encountered a critical internal
error during network initialization.
1
An invalid MAC address was encountered when the
library was initializing the RMU ethernet port.
3
An invalid IP subnet was detected when initializing
the RMU ethernet configuration.
1
The library firmware encountered a critical internal
error.
1
The library SCSI firmware encountered a critical
internal error.
2
The library SCSI firmware was not able to initialize
because an ADI-enabled drive was not detected.
1
The library control firmware detected an invalid
internal command.
1
The library control firmware detected that the
loader hardware was not ready.
1
The library control firmware detected an illegal
move attempted by an internal process.
4
The library door/switch is open and all robotics
operations are suspended until this condition is
cleared.
5
A host move medium command was attempted but
the library detected that the drive is in a prevent
medium removal state from the host.
1
The library control firmware detected a critical
internal error.
1
The library interprocess communications firmware
detected a critical internal error.
1
A motor fault condition was detected and the
library trace file is required for additional error
detail.
Troubleshooting and FSCs
3– 3

Advertisement

Table of Contents
loading

Table of Contents