Section 1

1.5.2 Technical Information

Operational Specifications
Mount time
Dismount time (excluding rewinding)
Inventory time (full including tape drives)
Rewind time (maximum / average)
Power Consumption
Idle State
Average Running State
Peak Power
Voltage
Input Voltage, Low
Input Voltage, High
Input Frequency
AC Power Input
BTU Heat Load
Maximum, one drive
Maximum, two drives
*. The low voltage nominal will be 110 VAC and the high voltage nominal will be 220 VAC.
†. Based on 3.415179 BTU/watt.
‡. ARCvault 24 only.

1.5.3 Reliability and Safety

Reliability
Mean time between failures (MTBF)
Maximum swaps before failure (MSBF)
Design life
Mean time to repair (MTTR)
Safety Standards
NRTL - US
NRTL - Canada
CE Marking (European Union)
TÜV GS Mark (Germany)
1–4
*
*
Less than 60 seconds, estimated
Less than 60 seconds, estimated
Less than 3 minutes
98 / 49 sec
80 Watts / 223 BTUs / 288 KJ
80 Watts / 223 BTUs / 288 KJ
165 Watts / 563 BTUs / 594 KJ
100-120 VAC ±10%
200-240 VAC ±10%
50-60 Hz
One IEC320-C14 type rear-panel receptacle
69.0 BTU/hour
96.9 BTU/hour
More than 250,000 hours
More than 1,000,000 cartridge swaps
7 years
Less than 30 minutes
IEC60950-1, Standard for Safety of Information
Technology Equipment
CAN/CSA-C22.2 No. 950, Standard for Safety of
Information Technology Equipment
Low Voltage Directive, 72/23/EEC, European Union
EN60950, (IEC950) Standard for Safety of
Information Technology Equipment, 3
rd
addition
10400025-101 10/2006