Hgm8140D Mlitary Genset Controller Back Panel - Smartgen HGM8140 User Manual

Genset controller
Hide thumbs Also See for HGM8140:
Table of Contents

Advertisement

6.2 HGM8140D MLITARY GENSET CONTROLLER BACK PANEL

No.
Function
1
B-
2
B+
3
TX
4
RS232
RX
5
GND
6
SCR
7
CAN
CANL
8
CANH
HGM8140 Military Genset Controller
HGM8140 MILITARY GENSET CONTROLLER USER MANUAL
Table 9 - Terminal Wiring Connection Description
Cable Size
2
2.5mm
2
2.5mm
2
0.5mm
2
0.5mm
2
0.5mm
/
2
1.0mm
2
1.0mm
Version 1.0
Remarks
Connected with negative of starter battery
Connected with positive of starter battery. If wire
length is over 30m, better to double wires in parallel.
Max. 20A fuse is recommended.
Connected with HGM8140M host controller.
Connected with HGM8140M host controller.
2016-12-07
Page 21 of 54