When Pr.544 = "1"; When Pr.544 = "12"; When Pr.544 = "14 Or 24" - Mitsubishi Electric A800-E Instruction Manual

Hide thumbs Also See for A800-E:
Table of Contents

Advertisement

(N) Operation via communication and its settings
 When Pr.544 = "1" (compatible with CC-Link Ver.1)
• Remote I/O (32 points)
Same as when Pr.544 = 0 (Refer to
• Remote register
Address

Upper 8 bits
RWwn
Monitor code 2
Set frequency (0.01 Hz increments) /
RWwn+1
torque command
Link parameter
RWwn+2
extended setting
RWwn+3
Write data

For the FR-A800-E, when Pr.804="3 or 5" during torque control under Real sensorless vector control or vector control, a torque command value
is set in RWwn+1.

"n" indicates a value determined according to the station number setting.
 When Pr.544 = "12" (Compatible with the double setting of CC-Link Ver.2)
• Remote I/O (32 points)
Same as when Pr.544 = 0 (Refer to
• Remote register
Address

Upper 8 bits
RWwn
Monitor code 2
Set frequency (0.01 Hz increments) /
RWwn+1
torque command
Link parameter
RWwn+2
extended setting
RWwn+3
Write data
RWwn+4
Monitor code 3
RWwn+5
Monitor code 4
RWwn+6
Monitor code 5
RWwn+7
Monitor code 6

For the FR-A800-E, when Pr.804="3 or 5" during torque control under Real sensorless vector control or vector control, a torque command value
is set in RWwn+1.

"n" indicates a value determined according to the station number setting.
 When Pr.544 = "14 or 24" (compatible with the quadruple setting of CC-Link Ver.2)
• Remote I/O (32 points (64 points occupied))
Same as when Pr.544 = 0 (Refer to
• Remote register
Address

Upper 8 bits
RWwn
Monitor code 2
RWwn+1
Set frequency (0.01 Hz increments)
Link parameter
RWwn+2
extended setting
RWwn+3
Write data
RWwn+4
Monitor code 3
RWwn+5
Monitor code 4
RWwn+6
Monitor code 5
RWwn+7
Monitor code 6
RWwn+8
Faults history No.
RWwn+9
PID set point (0.01% increments)
RWwn+A
PID measured value (0.01% increments)
RWwn+B
PID deviation (0.01% increments)
Torque command or torque limit
RWwn+C
Torque command or torque limit (1st
quadrant)

54
PARAMETER
page
53.)
Description
Refer to
Lower 8 bits
Monitor code 1
58
58

Instruction code
58
58
page
53.)
Description
Refer to
Lower 8 bits
Monitor code 1
58
58

Instruction code
58
58
58
58
58
58
page
53.)
Description
Lower 8 bits
Monitor code 1
Instruction code
H00



/

Address

page
Upper 8 bits
RWrn
First monitor value
RWrn+1
Second monitor value
RWrn+2
Reply code 2
RWrn+3
Read data
Address

page
Upper 8 bits
RWrn
First monitor value
RWrn+1
Second monitor value
RWrn+2
Reply code 2
RWrn+3
Read data
RWrn+4
Third monitor value
RWrn+5
Fourth monitor value
RWrn+6
Fifth monitor value
RWrn+7
Sixth monitor value
Refer to
Address

page
58
RWrn
First monitor value
58
RWrn+1
Second monitor value
58
RWrn+2
Reply code 2
58
RWrn+3
Read data
58
RWrn+4
Third monitor value
58
RWrn+5
Fourth monitor value
58
RWrn+6
Fifth monitor value
58
RWrn+7
Sixth monitor value
58
RWrn+8
Faults history No.
58
RWrn+9
Fault record (output frequency)
58
RWrn+A
Fault record (output current)
58
RWrn+B
Fault record (output voltage)
58,
63
RWrn+C
Fault record (energization time)
Description
Lower 8 bits
Reply code 1
Description
Lower 8 bits
Reply code 1
Description
Upper 8 bits
Lower 8 bits
Reply code 1
Fault data
Refer to
page
59
59
59
59
Refer to
page
59
59
59
59
59
59
59
59
Refer to
page
59
59
59
59
59
59
59
59
59
59
59
59
59