(D) Operation command and frequency command
The operation is as set in Pr.338 Communication operation command source and Pr.339 Communication speed command source. (Refer
to the Instruction Manual (Detailed) of the FR-A800/FR-F800 inverter.)
At occurrence of communication error, the inverter cannot be reset.
Enabled only when stopped by the PU. "PS" is displayed on the operation panel for the PU stop. The operation is as set in Pr.75 Reset
selection/disconnected PU detection/PU stop selection. (Refer to the Instruction Manual (Detailed) of the FR-A800/FR-F800 inverter.)
Writing of some parameters may be disabled by the Pr.77 Parameter write selection setting and the operating condition. (Refer to the
Instruction Manual (Detailed) of the FR-A800/FR-F800 inverter.)
Some parameters are write-enabled independently of the operation mode and command source presence/absence. Writing is also enabled
when Pr.77 = "2". (Refer to the Instruction Manual (Detailed) of the FR-A800/FR-F800 inverter.) Parameter clear is disabled.
Applicable when Pr.550 NET mode operation command source selection = "5" (Ethernet connector enabled), or Pr.550 NET mode
operation command source selection = "9999" with no communication option connected
Applicable when Pr.550 NET mode operation command source selection = "0 (communication option enabled)", or Pr.550 NET mode
operation command source selection = "9999" with communication option connected
The frequency can be set by multi-speed setting or input through terminal 4.
Operation at fault
Condition
Fault record
(Pr.551 setting)
Inverter fault
—
2 (PU connector)
9999 (automatic
PU connector
recognition)
disconnection
Other than 2
Communication
2 (PU connector)
error at PU
connector
Other than 2
3 (USB connector)
Communication
9999 (automatic
error at USB
recognition)
connector
Other than 3
5 (Ethernet board)
Communication
Other than 5 or
error at Ethernet
when the CC-Link
board
IE Field Network
Basic is selected
Communication
error at
—
communication
option
Selectable with Pr.75 Reset selection/disconnected PU detection/PU stop selection
Selectable with Pr.122 PU communication check time interval, Pr.548 USB communication check time interval, and Pr.1432 Ethernet
communication check time interval
The operation depends on the communication option setting.
In the PU JOG operation mode, the operation always stops when the PU is disconnected. The operation at a PU disconnection fault (E.PUE)
occurrence is as set in Pr.75 Reset selection/disconnected PU detection/PU stop selection.
Applicable when Pr.550 NET mode operation command source selection = "5" (Ethernet connector enabled), or Pr.550 NET mode
operation command source selection = "9999" with no communication option connected
Applicable when Pr.550 NET mode operation command source selection = "0 (communication option enabled)", or Pr.550 NET mode
operation command source selection = "9999" with communication option connected
12
PARAMETER
Operation in each operation mode at error occurrences
External
PU
(EXT)
operation
operation
Stop
Stop/continued
Stop/continued
Stop/
Continued
continued
Continued
Stop/
Continued
continued
Continued
Stop/
Continued
continued
Continued
Continued
EXT/PU
EXT/PU
combined
combined
operation
operation
mode 1
mode 2
(Pr.79 = 3)
(Pr.79 = 4)
Stop/
continued
Stop/
continued
NET operation
NET operation
(when the
(when a
Ethernet
communication
connector is
option is
used)
used)
Continued
Continued
Stop/continued
Continued
Stop/continued