(N) Operation via communication and its settings
Ethernet IP address for command source selection (Pr.1449 to Pr.1454)
• To limit the network devices that send the operation or speed command through the Ethernet network (Modbus/TCP or CC-
Link IE Field Network Basic), set the range of IP addresses of the devices.
• When Pr.1449 to Pr.1452 = "0 (initial value)", no IP address is specified for sending commands through the Ethernet
network. In this case, operation through the Ethernet network (Modbus/TCP or CC-Link IE Field Network Basic) is not
available.
• When four or more clients attempt a connection to the inverter during Modbus/TCP communication, the connection
attempted from outside of the IP address range set for Ethernet command source selection may be forced to be closed.
• The setting range for command source selection depends on the settings in Pr.1451 and Pr.1453, and Pr.1452 and
Pr.1454. (Either of the settings can be larger than the other in Pr.1451 and Pr.1453, and Pr.1452 and Pr.1454.)
[Setting example 1]
Ethernet IP address
for command source selection
Command source selection range setting
for the Ethernet IP address
In this case, the IP address range for command source selection via Ethernet communication is
"192.168.x (1 to 3).xxx (100 to 150)".
[Setting example 2]
Ethernet IP address
for command source selection
Command source selection range setting
for the Ethernet IP address
In this case, the IP address range in which Ethernet communication is permitted is "192.168.2.xxx (50 to 100)".
• When "9999 (initial value)" is set in Pr.1453 and Pr.1454, the range is invalid.
24
PARAMETER
Pr.1449
Pr.1450
Pr.1451
192
168
The range is between
the values set in both
parameters.
Pr.1453
Pr.1449
Pr.1450
Pr.1451
192
168
The range is between
the values set in both
parameters.
Pr.1453
Pr.1452
1
100
The range is between
the values set in both
parameters.
Pr.1454
3
150
Pr.1452
2
100
Pr.1454
9999
50