Real Time Monitor; Parameters - Mitsubishi Electric A800-E Instruction Manual

Hide thumbs Also See for A800-E:
Table of Contents

Advertisement

• Real time monitor

For the details of the register numbers and the monitor items for the real time monitor, refer to the description of Pr.52 in the
Instruction Manual (Detailed) of the FR-A800/FR-F800 inverter.

• Parameters

Pr.
Register
Refer to the Instruction Manual
41000 to
0 to 999
(Detailed) of the FR-A800/FR-F800
41999
inverter for parameter names.
Terminal 2 frequency setting bias
C2 (902)
41902
(frequency)
Terminal 2 frequency setting bias
42092
(analog value)
C3 (902)
Terminal 2 frequency setting bias
43902
(terminal analog value)
Terminal 2 frequency setting gain
125 (903)
41903
(frequency)
Terminal 2 frequency setting gain
42093
(analog value)
C4 (903)
Terminal 2 frequency setting gain
43903
(terminal analog value)
Terminal 4 frequency setting bias
C5 (904)
41904
(frequency)
Terminal 4 frequency setting bias
42094
(analog value)
C6 (904)
Terminal 4 frequency setting bias
43904
(terminal analog value)
Terminal 4 frequency setting gain
126 (905)
41905
(frequency)
Terminal 4 frequency setting gain
42095
(analog value)
C7 (905)
Terminal 4 frequency setting gain
43905
(terminal analog value)
C12 (917)
41917
Terminal 1 bias frequency (speed)
42107
Terminal 1 bias (speed)
C13 (917)
Terminal 1 bias (speed)
43917
(terminal analog value)
C14 (918)
41918
Terminal 1 gain frequency (speed)
42108
Terminal 1 gain (speed)
C15 (918)
Terminal 1 gain (speed)
43918
(terminal analog value)
Terminal 1 bias command (torque/
C16 (919)
41919
magnetic flux)
42109
Terminal 1 bias (torque/magnetic flux)
C17 (919)
Terminal 1 bias (torque/magnetic flux)
43919
(terminal analog value)
Terminal 1 gain command (torque/
C18 (920)
41920
magnetic flux)
42110
Terminal 1 gain (torque/magnetic flux)
C19 (920)
Terminal 1 gain (torque/magnetic flux)
43920
(terminal analog value)
Motor temperature detection
42115
calibration (analog input)
C29 (925)
Motor temperature detection
43925
calibration (analog input)
(terminal analog value)
C30 (926)
41926
Terminal 6 bias frequency (speed)
42116
Terminal 6 bias (speed)
C31 (926)
Terminal 6 bias (speed)
43926
(terminal analog value)
C32 (927)
41927
Terminal 6 gain frequency (speed)
42117
Terminal 6 gain (speed)
C33 (927)
Terminal 6 gain (speed)
43927
(terminal analog value)
C34 (928)
41928
Terminal 6 bias command (torque)
(N) Operation via communication and its settings
Parameter name
Read/write
Read/write
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Remarks
The parameter number +41000 is the register number.
Analog value (%) set to C3 (902)
Analog value (%) of the voltage (current) applied to
terminal 2
Analog value (%) set to C4 (903)
Analog value (%) of the voltage (current) applied to
terminal 2
Analog value (%) set to C6 (904)
Analog value (%) of the current (voltage) applied to
terminal 4
Analog value (%) set to C7 (905)
Analog value (%) of the current (voltage) applied to
terminal 4
Analog value (%) set to C13 (917)
Analog value (%) of the voltage applied to terminal 1
Analog value (%) set to C15 (918)
Analog value (%) of the voltage applied to terminal 1
Analog value (%) set to C17 (919)
Analog value (%) of the voltage applied to terminal 1
Analog value (%) set to C19 (920)
Analog value (%) of the voltage applied to terminal 1
Analog value (%) between terminals TH1 and TH2 of the
FR-A8AZ
Analog value (%) set to C31 (926)
Analog value (%) of the voltage applied to terminal 6 of
the FR-A8AZ
Analog value (%) set to C33 (927)
Analog value (%) of the voltage applied to terminal 6 of
the FR-A8AZ
PARAMETER