Selection Of The Command Source During Communication Operation; D) Operation Command And Frequency Command - Mitsubishi Electric A800-E Instruction Manual

Hide thumbs Also See for A800-E:
Table of Contents

Advertisement

2.3
(D) Operation command and frequency
command
Purpose
To select the command source
during communication operation
To select the torque command
method in the torque control
mode
2.3.1
Selection of the command source during
communication operation
When the Ethernet connector or a communication option is used, the command source in the network (NET) / PU
operation mode can be selected.
Pr.
550
NET mode operation command
D012
source selection
551
PU mode operation command
D013
source selection
Selection of command source in the network (NET) operation mode
(Pr.550)
• Either of the Ethernet connector or the communication option can be specified for the command source in the NET
operation mode.
• For example, whether or not the communication option is mounted, set Pr.550 = "5" to write parameters or input the start
and frequency commands via the Ethernet connector in the NET operation mode.
NOTE
• In the initial setting, "9999" (communication option automatic recognition) is set for Pr.550. Thus, if the communication option
is mounted, parameters cannot be written or the start and frequency commands cannot be sent by communications that use
the Ethernet connector. (Monitoring or parameter reading can be performed.)
Selection of the command
source during
communication operation
Torque command source
selection
Name
Initial value
9999
9999

(D) Operation command and frequency command

Parameter to set
P.D012, P.D013
P.D400
Setting range
The communication option is the
0
command source when in the NET
operation mode.
1
For manufacturer setting. Do not set.
The Ethernet connector is the command
5
source when in the NET operation mode.
Communication option automatic
recognition
Normally, the Ethernet connector is the
9999
command source. When the
communication option is mounted, the
communication option is the command
source.
1
For manufacturer setting. Do not set.
The PU connector is the command
2
source when in the PU operation mode.
The USB connector is the command
3
source when in the PU operation mode.
The Ethernet connector is the command
5
source when in the PU operation mode.
USB automatic recognition
Normally, the PU connector is the
9999
command source. When the USB is
connected, the USB connector is the
command source.
Refer to
page
Pr.550, Pr.551
9
Pr.804
51
Description
PARAMETER
2
GROUP
D
9

Advertisement