6.2

I/O signal list

6.2.1
I/O signal when CC-Link ver.1 one station (FR-E500 series compatible)
is occupied (Pr. 544 = 0)
(1) Remote I/O (32 points)
Device
No.
RYn0
Forward rotation command
RYn1
Reverse rotation command
High-speed operation command
RYn2
(terminal RH function)
Middle-speed operation command
RYn3
(terminal RM function)
Low-speed operation command
RYn4
(terminal RL function)
RYn5
Not used
RYn6
Second function selection (RT signal)
RYn7
Terminal 4 input selection (AU signal)
RYn8
Not used
RYn9
Output stop (MRS signal)
RYnA
Not used
RYnB
Reset (terminal RES function)
RYnC
Monitor command
RYnD
Frequency setting command (RAM)
Frequency setting command
RYnE
(RAM, EEPROM)
RYnF
Instruction code execution request
Refer
Signal
Page
*1
*1
*1
*2
*2
*1
*1
Device
to
No.
51
RXn0
Forward running
51
RXn1
Reverse running
51
RXn2
Running (terminal RUN function)
51
RXn3
Up to frequency (SU signal)
51
RXn4
Overload alarm (OL signal)
RXn5
Not used
Frequency detection
51
RXn6
(terminal FU function)
RXn7
Error (terminal ABC function)
51
RXn8
Not used
51
RXn9
Pr. 313 assignment function (DO0)
RXnA
Pr. 314 assignment function (DO1)
RXnB
Pr. 315 assignment function (DO2)
51
52
RXnC
Monitoring
52
RXnD
Frequency setting completion (RAM)
Frequency setting completion
RXnE
52
(RAM, EEPROM)
52
RXnF
Instruction code execution completion
I/O SIGNAL LIST
Refer
Signal
Page
*3
*3
*3
*4
*4
*4
to
53
53
53
53
53
53
53
53
6
53
53
53
54
54
54
43