Ethernet function selection (Pr.1427 to Pr.1429)
Refer to the Instruction Manual of the device connected via Ethernet, and set Pr.1427 to Pr.1429 Ethernet function
selection 1 to 3 according to the application and protocol.
A communication socket is provided only for the selected application.
Pr.1427 to Pr.1429
setting
502
5000
5001 (Pr.1427 initial value)

5002

5006
5007
5008
5010
5011
5012
5013
45237 (Pr.1428 setting)
61450
9999 (Pr.1429 initial value)

If both application and protocol settings are identical in Pr.1427 to Pr.1429, the priority of the setting is defined as follows: Pr.1427 > Pr.1428 >
Pr.1429.
(Example) When Pr.1427 = "5001", Pr.1428 = "5006", Pr.1429 = "5013", "5001" and "5013" are valid.

To connect the inverter and FR Configurator2 via the MELSOFT / FA product for Ethernet communication, set "5001 (initial value)" or "5002"
according to the protocol type (UDP/IP or TCP/IP) in any of Pr.1427 to Pr.1429.

When the inverter is connected with other equipment via a hub, and if the communication between the other equipment and the hub is
interrupted and resumed, the communication between the inverter and the other equipment may not be established depending on the
specifications of the hub. To re-establish communication with the other equipment, reset the inverter to forcefully close the connection. (Setting a
shorter time in Pr.1455 Keepalive time is also effective as a preventive measure (refer to

For details, refer to the Instruction Manual of FR Configurator2.
Communication speed and full-duplex/half-duplex selection (Pr.1426)
Set the communication speed and the communication mode (full-duplex/half-duplex) in Pr.1426 Link speed and duplex
mode selection.
If the operation is not performed properly in the initial setting (Pr.1426 = "0"), set Pr.1426 according to the specifications of the
connected hub.
Pr.1426 setting
Communication speed
0 (initial value)
Automatic negotiation
1
100 Mbps
2
100 Mbps
3
10 Mbps
4
10 Mbps
Application

Modbus/TCP
MELSOFT / FA product connection
SLMP
iQSS
CC-Link IE Field Network Basic
Unselected
Full-duplex/half-
duplex system
Automatic negotiation
Full-duplex
Half-duplex
Full-duplex
Half-duplex
(N) Operation via communication and its settings
Number of
Protocol

connectable clients
TCP/IP
3
UDP/IP
No limit
TCP/IP
1

UDP/IP
No limit
TCP/IP
1

UDP/IP
No limit
UDP/IP
No limit
TCP/IP
1

UDP/IP
No limit
UDP/IP
No limit
page
22).)
The communication speed and the communication mode
(half-duplex/full-duplex) are automatically negotiated to
ensure the optimum setting.
Refer to
page
39
26
27

51
Remarks
PARAMETER
2
GROUP
N
21