Melsoft / Fa Product Connection - Mitsubishi Electric A800-E Instruction Manual

Hide thumbs

Advertisement

(N) Operation via communication and its settings
2.5.3

MELSOFT / FA product connection

FR Configurator2, GOT, or a relay station (programmable controller) can be connected via Ethernet.
Initial setting
• Set any value from "5000 to 5002, 5006 to 5008" in any of Pr.1427 to Pr.1429 Ethernet function selection 1 to 3 to select
the MELSOFT / FA product connection for the application. (For how to set the application value, refer to the Instruction
Manual of the device connected via Ethernet.) (Refer to
• Enter the Ethernet communication network number in Pr.1424 and the Ethernet communication station number in Pr.1425.
(Refer to
page
25.)
• Enable the PLC function (Pr.414 PLC function operation selection  "0 (initial value)") to use FR Configurator2
(Developer). (For the details of Pr.414, refer to the Instruction Manual (Detailed) of the FR-A800/FR-F800 inverter.)
System configuration
• Direct connection with FR Configrator2
• Direct connection with GOT
• Connection using a relay station (programmable controller)
26
PARAMETER
page
21.)
Ethernet cable
Personal computer
(FR Configurator2)
Ethernet cable
GOT
Ethernet cable
Relay station
(programmable controller)
Inverter
Inverter
Inverter