Ethernet Programming Options - DSC TL280R Installation Manual

Internet alarm communicator - international
Hide thumbs Also See for TL280R:
Table of Contents

Advertisement

Ethernet Programming Options

Table 6: Trouble indications
Trouble
Trouble
Indicator
indication
Digit
Red and Yellow
LEDs flashing
N/A
together
E
The programming sections described in this document can be viewed at the keypad LCD. To start
programming enter: [*][8][installer code][851][section number], where section number is the 3
digit section number referenced in this section. The programming worksheets at the end of this
document can be used to record the new values when programming changes have been made from
the default values.
Possible
Causes
• The unit is still initializing please wait while the unit gets its programming
Initialization
and establishes a connection to all programmed receivers.
Sequence
NOTE: This process may take several minutes to complete.
• If the initialization sequence is taking more than several minutes, the boot
loader might have failed.
• Confirm that the boot loader has failed by entering communicator program-
Boot Loader
ming [*][8][installer code][851].
Failed
• If access is granted, continue waiting for the initialization sequence to com-
plete.
• If access is denied (long error tone), disconnect power from, then recon-
nect power to the communicator module.
P