Enter the Domain Name as 32 ASCII characters. This information will be provided by the central station system admin-
istrator.

Cellular Receiver 2 Options

[211] Cellular Receiver 2 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between different transmitters. This account code is used
when transmitting signals to the central station receiver. Signals received on the panel will use the panel account number.
Valid range: 0000000001 - FFFFFFFFFE.
NOTE: Programming this section as all 0's or F's will cause a module configuration trouble (yellow LED = 12 flashes).
[212] Cellular Receiver 2 DNIS
Default (000000)
The DNIS is used in addition to the account code to identify the communicator module at the central station. Valid range:
000000 - 099999. Values are entered as a 0 followed by the 5-digit DNIS value. Format is BCD.
[213] Cellular Receiver 2 Address
Default (000.000.000.000)
Enter the cellular receiver 2 IP address. This IP address will be provided by the central station. Format is 4 fields, each field
is 3-digit decimal. Valid range: 000 - 255.
NOTE: When a valid address has been entered, cellular receiver 2 is enabled and will communicate events over the cel-
lular path.
[214] Cellular Receiver 2 Port
Default (0BF5/3061)
This section defines the port of cellular receiver 2. Change the value of this port when the installation is located behind a fire-
wall and must be assigned a particular port number, as determined by the central station system administrator. Valid range:
0000 - FFFF.
NOTE: Do not program cellular receiver 1 and cellula r receiver 2 to communicate to the same receiver.
[215] Cellular Receiver 2 APN
Default (   )
The APN determines the cellular network that the communicator will connect to. This information is available from the net-
work carrier. Program this section with up to 32 ASCII characters.
NOTE: When a SIM card with a custom APN is used, the unit will not have access to the Internet. DLS and remote flash can
still be done if section [221] is programmed with a valid public APN.
[216] Cellular Receiver 2 Domain Name
Default (   )
Enter the cellular receiver 2 Domain Name with up to 32 ASCII characters.

Cellular Options

[221] Cellular Public Access Point Name
Default (   )
When the communicator is operating on a private APN, use this section to select a public APN for DLS and remote firmware
update. This information is available from the network carrier. The APN identifies the public cellular network that the com-
municator will connect to.
[222] Cellular Login User Name
Default (   )
Some network carriers require login credentials when connecting to an APN. Program the login user name in this section.
Enter the Cellular Login User Name with up to 32 ASCII characters.
[223] Cellular Login Password
Default (   )
Some network carriers require login credentials when connecting to an APN. Program the login password in this section.
Enter the Cellular Login Password with up to 32 ASCII characters.
[224] Cellular Test Transmission Time of Day
Default (9999)
Enter a 4-digit value using the 24-hour clock format (HHMM) to set the test transmission time of day. Valid range: 00-23 for
the hours (HH) and 00-59 for the minutes (MM).
NOTE: To disable the test transmission time of day enter 9999 or FFFF in this section.
The internal date and time will be automatically programmed by the primary receiver only.