Rectifying faults
Resetting welding parameters to the factory settings
Error message
Err 38
Err 39
Err 40
Err 48
Err 49
Err 51
Err 57
Err 59
If the industrial bus interface is connected error messages are output via the respective interface.
It may occur that error messages output from the power source and the interface differ.
7.4
Resetting welding parameters to the factory settings
All customised welding parameters that are stored will be replaced by the factory settings.
To reset the welding parameters or machine settings to the factory settings, select parameter
service menu
7.5
Display machine control software version
The query of the software versions only serves to inform the authorised service staff. It is available in the
machine configuration menu > see 5.9 chapter.
68
Possible cause
---
Electronics error (secondary
overvoltage)
Electronics error (I>0 error)
Ignition error
Arc interruption
Error in emergency stop circuit
(interface for automated welding)
Auxiliary drive error, tacho error
Incompatible component
> see 5.9 chapter.
Remedy
Switch the machine off and on again.
If the error persists, contact service.
Inform service
Check welding process
Inform service
•
Check the external interrupt equipment
•
Check jumper JP 1 on PCB T320/1
Check the auxiliary drive (tacho – no signal,
M3.51 defective > inform service)
Replace component
in the
099-000141-EW501