EWM Tetrix 352 Synergic Operating Instructions Manual page 61

Hide thumbs Also See for Tetrix 352 Synergic:
Table of Contents

Advertisement

Display
1
for AC welding machines only.
2
For machines with filler wire (AW) only.
3
for components for automated welding (RC) only.
099-000141-EW501
20.11.2017
Setting/selection
Automated/Manual (rC on/off) operating mode
Select machine/function control
------
with external control voltages/signals
------
with machine control
Software version query (example)
07.= ------ system bus ID
03c0= ---- version number
System bus ID and version number are separated by a dot.
Cable resistance alignment
Only qualified service personnel may change the parameters!
TIG HF start (soft/hard) switching
------- soft ignition (factory setting).
------- hard ignition.
Ignition pulse limit
Setting 0 ms–15 ms (increments of 1 ms)
PCB state – qualified service personnel only!