Design and function
Interfaces for automation
Pin
Signal
shape
E
Input
F
Input
G
Output
H
Output
J
Output
K
Input
L
Input
M
Output
N
Input
P
Input
R
Input
S
Output
T
Output
U
Input
V
Output
54
Circuit diagram
Function
signal name
Not/Aus
Emergency stop for higher level shut-down of the power
source.
To use this function, jumper 1 must be unplugged on PCB
T320/1 in the welding machine.
Contact open welding current switched off
Sollwert Absenkstrom Control voltage specification for secondary current,
0-10 V (0 V = I
IGRO Relais
Current flows signal
I > 0
Contact closed = welding current flowing
(forms contact with signal D)
Prozeßspannung Uist Actual welding voltage, measured on pin S,
0-10 V (0 V = 0 V, 10 V = 100 V)
SYN_A E
Synchronisation for master/slave operation
SYN_A C
Str./Stp.
Start/stop welding current, same as torch trigger.
Only available in non-latched operating mode.
+15 V = Start, 0 V Stop
+15V
Power supply
+15 V, max. 75 mA
Sollwert Hauptstrom
Control voltage specification for main current,
0-10 V (0 V = I
Sollwert Frequenz
Nominal frequency value
0-10 V (0 V= 50 Hz, 10 V = 0.1 Hz)
Not/Aus
Emergency stop for higher level shut-down of the power
source.
To use this function, jumper 1 must be unplugged on PCB
T320/1 in the welding machine.
Contact open welding current switched off
0V
Reference potential
Prozessstrom Iist
Welding current, measured on pin S,
0-10 V (0 V = 0 A, 10 V = 1000 A)
BR. KOLL. 1
Emergency shut-down collision protection +24 V
BR. KOLL. 2
Emergency shut-down collision protection
min
/10 V = I
)
max
min
/10 V = I
)
max
099-000141-EW501
20.11.2017