DME4io-ES/DME8i-ES/DME8o-ES
Note
When the test is completed, switch positions will be set to the factory default.
Troubleshooting
Check the signals coming through the CN350 of the DSP circuit board in case of NG.
Or some dip switch may be defective.
3-15. AD Test (NO. 19)
Contents: PHANTOM/GAIN are changed and checks if they are set correctly.
Preparations: • Install a card such as MY16AE that can send and receive AES/EBU on the 01V96.
• When inspecting the 48 kHz AD, set up I/O Patch of the NAI48-ES as shown in the fi gure below
through the AVS-ES Monitor on the PC. Set up the I/O Patch in the same way when inspecting the 48
kHz DA.
• When inspecting the 96 kHz AD, set up the I/O Patch of the NAI48-ES as shown in the fi gure below
through the AVS-ES Monitor on the PC. Set up the I/O Patch in the same way when inspecting the 96
kHz DA.
68
PC
NAI48-ES
Switching Hub
DME Satellite
CAUTION:
Connect as shown in the figure above for AD test or DA test.
[Names of connectors to be used]
EtherSound IN connector
NETWORK connector
EtherSound OUT connector
EtherSound IN connector
INPUT connector
AES/EBU
Mixer
01V96, etc.