Yamaha DME4io-ES Service Manual page 58

Digital mixing engine satellite
Hide thumbs Also See for DME4io-ES:
Table of Contents

Advertisement

DME4io-ES/DME8i-ES/DME8o-ES
3-2.
BATTERY Test (NO. 02)
Contents: Checks the voltage of the backup battery automatically by measuring it in A/D.
The measured battery voltage is displayed.
Example of Executing Screen
***
02. BATTERY
VOLTAGE: 3.05[V]
OK.
VOLTAGE: 2.50[V]
NG: BATTERY LOWER ERROR!
EXIT:[ENTER]
Messages
• At battery overvoltage:
• At shortage of battery voltage:
• At lower battery voltage:
Troubleshooting
Check backup battery (CPU circuit board: BT001) and the path from the backup battery to the PTK [1] (114Pin) and
AN [6] (238Pin) of the CPU (CPU circuit board: IC002).
Applicable Range of Measured Voltage
• Acceptable voltage range
• Overvoltage
• Low voltage
• Voltage shortage
3-3.
PLLP2 Test (NO. 03)
Contents: Checks register (00h,0Fh,10h,16h) of PLLP2 by writing/reading and comparing them.
Example of Executing Screen
***
03. PLLP2
0x00 W/R OK!
0x0F W/R OK!
0x10 W/R OK!
0x16 W/R 0x16 W:0x0F R:0x00
EXIT:[ENTER]
Troubleshooting
Check the followings in case of NG.
Check malfunction of PLLP2 (DSP circuit board: IC052) and signal path (address bus, data bus, control signal, etc.)
connected between the PLLP2 and CPU (CPU circuit board: IC002).
58
***
NG: BATTERY OVER ERROR!
NG: BATTERY EMPTY ERROR!
NG: BATTERY LOWER ERROR!
2.80 [V] – 3.50 [V]
3.51 [V] or over
2.79 [V] – 0.51 [V]
0.5 [V] or under
***
Indicated in case of OK
Indicated in case of NG
Indicated in case of OK
Indicated in case of NG

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dme8i-esDme8o-es

Table of Contents