Yamaha DME4io-ES Service Manual page 106

Digital mixing engine satellite
Hide thumbs Also See for DME4io-ES:
Table of Contents

Advertisement

DME4io-ES/DME8i-ES/DME8o-ES
WRITING COMPONENT/SCENE DATA
1.
Connection to PC
Connect the LAN terminal of the PC and the NETWORK terminal of the DME Satellite with a LAN cross cable.
2.
Activating the DME Satellite
Set the DIP SWITCH as follows and turn on the power to the DME Satellite.
Left
U U U U D D
U: Up
D: Down
3.
Activating the software for writing component/scene data
Click on the icon "sync" of C:¥TOOLS_SATELLITE¥tools¥sync¥component¥.
4.
Setting the parameters
Set the parameters according to the following parameters.
Output Port
: ZONE1
Input port
: ZONE1
Target ID
: 2
Execution fi le
: C:¥TOOLS_SATELLITE¥component¥DMESATELLITE.dat
Component data writing can be started if all the parameters are correct.
5.
Writing component/scene data
Click on "Execute...".
The writing is fi nished when the "Command execution fi nished" is displayed.
All DIP SWITCH set to the upper position.
106
Right
[Setting and executing screen]