2 ] Interface Cable Connection - Denso BHT-100BW-CE User Manual

Bar code handy terminal
Table of Contents

Advertisement

Chapter 5 Handling the
CU-7000
(Option)

[ 2 ] Interface Cable Connection

As illustrated below, connect the CU-7000 (on which the BHT is put) to a host computer with a
cross-mode cable. To connect it to a modem, use a straight-mode cable.
Cable Connection between CU-7000 and Host Computer
Cable Connection between CU-7000 and Modem
DTE and DCE
In the RS-232C interface specifications, the DTEs (Data Terminal Equipment) shall be generally
connected with each other by a cross-mode cable; the DTE and DCE (Data Circuit-terminating
Equipment) shall be connected with each other by a straight-mode cable.
The DTE is one piece of equipment connected at both ends of a communications line as a sender or
receiver of data (such as CU-7000 on which the BHT is put and a host computer).
The DCE is one piece of equipment connected to the intermediate point between the DTE and the
communications line. It terminates communications lines and exchanges information between those
lines without any change in contents (such as modem).