WEG CFW-10 EASYDRIVE User Manual page 79

Table of Contents

Advertisement

FAULT
E04
Power-on
Inverter
Manual (key
Overtemperature
Auto-reset
DI
E05
Overload
at output
Ixt Function
E06
External Error
digital input progra
for ext. fault is open)
E08
CPU Error
E09
Contact WEG
Program Memory
(refer to section 7.3)
Error (Checksum)
E24
It is automatically reset
Programming
when the incompatible
error
parameters are changed
E31
Contact WEG
Keypad (HMI)
Servicing
Connection Fault
(Refer to Item 7.3)
E41
Contact WEG Servicing
Self- Diagnosis
(refer to section 7.3)
Fault
DIAGNOSTICS AND TROUBLESHOOTING
CHAPTER 7 -
RESET
(1)
)
Note:
(1)
In case of E04 Fault due to inverter overtemperature,
allow the inverter to cool down before trying to reset it.
The faults act as follows:
E00 to E06: switches off the relay that has been
programmed to "no fault", disables the PWM pulses,
displays the fault code on the display Some data are saved
on the EEPROM memory: keypad reference and EP
(electronic potentiometer) (when the function "backup of
the references" at P120 has been enabled), the occurred
fault number, the status of the integrator of the IxT function
(overcurrent).
E24: Indicates the fault code on the LED display.
E08, E09, E31 e E41: do not allow inverter operation (it is
not possible to enable the inverter); the fault code is
indicated on the LED display.
POSSIBLE CAUSES
Ambient temperature too high (>50ºC) and/or output current
too high.
NOTE
The heat sink overtemperature protection (E04) is activated
when the heat sink temperature (P008) reaches 103ºC.
P156 set too low for the motor that is being used.
Motor is under an actual overload condition.
Wiring at DI1 to DI4 inputs is open (not connected to
GND (pin 5 of the XC1 control connector)].
Electrical noise.
Memory with corrupted values.
Incompatible parameters were programmed
Refer to table 5.1.
Inverter control circuit is defective.
Electrical noise in the installation (electromagnetic
interference).
Inverter power circuit is defective.
79