CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
[Factory Setting]
Parameter
P300
DC Braking
Time
P301
DC Braking
Start Frequency
P302
Braking Torque
(1)
This parameter can be changed only with disabled inverter (stopped motor).
76
Range
Unit
CFW100016S ...
CFW100026S ...
CFW100040S ...
CFW100073S ...
0.0 to 15.0s
The DC braking feature provides a motor fast stop via
[ 0.0 ]
DC current injection.
0.1s
The applied DC braking current, that is proportional to
the braking torque, is set at P302.
0.0 to 15.0Hz
The figures below show the DC branking operation at
[ 1.0Hz ]
the two possible conditions: ramp disabling and general
0.1Hz
disabling.
0.0 to 100%
[ 50.0% ]
0.1%
Before DC braking starts, there is a "Dead Time" (motor
runs freely) required for the motor demagnetization. This
time is function of the motor speed at which the DC
braking occurs (output frequency)
During the DC braking the LED display flashes
If the inverter is enabled during the braking process, this
process will be aborted and motor operates normally.
Description / Notes
Inverter Model
2.5 kHz to
/ P297
Outpuit
frequency
(Motor
speed)
DI - Start/Stop
Figure 6.21 - DC braking after ramp disable
Outpuit
frequency
(Motor
speed)
DI- General
Enable
Figure 6.22 - DC braking after general disable
10.1 kHz to
5.0 kHz
15.0 kHz
1.6A
1.6A
2.1A
2.6A
3.4A
4.0A
6.3A
7.3A
DC Current
INJECTION
P300
P301
DEAD
TIME
0V
open
IDC Current
INJECTION
P300
DEAD
TIME
0V
open
5.1 kHz to
10.0 kHz
1.6A
2.6A
4.0A
6.8A
Time
Time
.