CHAPTER 5 - KEYPAD (HMI) OPERATION
If one DI has been set to JOG (P263 to P266 = 3) and no other DI has been set to General Enable or Ramp (P263
to P266 ≠ 1 or 2 ou 4 or 9 or 13).
Two or more DI(s) programmed to the same valuer (P263 to P266 = 3 to 6, 9 to 21).
In one DI is set to FWD (P263 to P266 = 9 or 11) and no other DI has been set to REV (P263 to P266 = 10 or 12).
One DI programmed to ON (P263 to P266 = 13) and no other DI has been set to OFF (P263 to P266 = 14).
One DI programmed to Accelerate (P263 to P266 = 16 or 18) and no other DI has been set t Deceleerate (P263 to
P266 = 17 or 19).
DI(s) programmed to the function FWD/REV (P263 to P266 = [9 or 11] e [10 or 12]), and simultaneously other DI(s)
have been programmed to the functions ON/OFF (P263 to P266 = 13 and 14).
Reference programmed to Multispeed (Local or Remote - P221 and/or P222 = 6) and there are no DI(s) programmed
to Multispeed (P263 to P266 = 7 or 8).
Reference programmed to E.P. (Local or Remote - P221 and/or P222 = 2) nd there are no DI(s) programmed to
Accelerate/Decelerate E.P. (P263 to P266 = 16 to 19).
There is command selected to Local and/or Remote (P229 and/or P230 = 1) and there is no DI programmed to
General Enable or Ramp or FWD/REV or ON/OFF (P263 to P266 = 1, 2, 4, 13, 14, 9, 10).
The DI1 and the DI2 (P263 and P264 = 7 or 8) have been programmed simultaneously to Multispeed
48
NOTE!
(1)For parameters that can be changed with the running mo-
tor , the inverter will use the new value immediately after it
has been set. For parameters that can be changed only
with stopped motor , the inverter will use this new value only
after the key
(2)By pressing the
programmed value will be saved automatically in the volatile
memory and will remain stored there until a new value is
programmed.
(3)If the last programmed value in the parameter is not
functionally compatible with the other parameter values
already programmed, the E24 - Programming Error - will
be displayed.
Example of programming error:
Programming of two digital inputs (DI) with the same
function. Refer to table 5.1 for list of programming errors
that can generate an E24 Programming Error.
(4)To change any paramater value, you must set before
P000 = 5.
Otherwise you can only read the parameter values, but not
reprogram them. For more details, see P000 description
in Chapter 6.
Table 5.1 - Incompatibility between Parameters - E24
is pressed.
key after the reprogramming, the new