Service Screen - Siemens SIJECT15 Operation Manual

Software version 1
Table of Contents

Advertisement

SIJECT OP15B Screens

3.1.10 Service screen

Operating sequences
Press this key to enter the service screen. See Fig 3-22 Service screen 1
--- parameter setting.
On service screen, input password 2 (2000) before any parameter
setting. Then, confirm your entry by "Enter" key.
Parameter setting
See Fig. 3-22 Service screen 1 --- parameter setting.
Carriage retract mode (CarRetMod) - Carriage retract can be set as
position mode or time mode.
Photo sensor mode (CycSenNSTD) - Photo sensor can be set as
normally open mode or normally close mode.
Lubrication error (LubErrNSTD) - Contactor in alarm circuit can be
set as normally open mode or normally close mode.
Fast mold open (FastMldOpn) - It can be set as normal mode or
special mode.
Motor protection (MotStrPro) - Motor protection can be selected, i.e.,
if there is delay time during motor star triangle startup. Motor protection
can also be deselected.
Special function 1 (SpecSel 1) - Spare.
Special function 2 (SpecSel 2) - Spare.
Number of screw cams (ScrewCam) - The cam numbers set on the
screw during screw speed measurement. Range: 1~255.
3-26
Fig 3-22
Service screen 1 – parameter setting
SIJECT 15/16 Operation Manual June, 2003

Advertisement

Table of Contents
loading

This manual is also suitable for:

Siject16

Table of Contents