SIJECT OP15B Screens
Secondly, select valve type, such as pressure valve; then select valve
limit, such as maximum:
Choose "Max." in valve limit, and change its value by softkey:
1. Use cursor key
2. Press selection key
3. Use cursor key
4. Confirm it with Enter Key;
5. Press softkey F3 "+" to increase the "Max."; or use softkey F4"-"
to reduce "Max.". This process can be observed by external
amperemeter.
Lastly, check the adjustment result:
In the "Force Output" mode, implement the "Pressure Test":
1. Press softkey F2 "Force Output", and the upper box will backlight;
2. Set the value of 140bar in Pressure Test;
3. Check if the external amperemeter reaches the maximum, such as
1Amp.
3-32
or
to enter valve adjustment selection;
, and cursor moves to left;
or
to select "Max.";
SIJECT 15/16 Operation Manual June, 2003