Temperature setting
On service screen 1, press softkey F2
- linear scale setting. Then, press softkey F4
temperature setting screen. Temperature channel can be set from 1 to 5,
and temperature can be set accordingly.
Temperature Tolerance Plus --- set the tolerance plus for each
temperature channel.
Temperature Tolerance Minus --- set the tolerance minus for each
temperature channel.
Oil Upper --- set the upper limit of hydraulic oil temperature.
Oil Lower --- set the lower limit of hydraulic oil temperature.
Temperature Compensation --- set the temperature compensation. The
system has been set the compensation before delivery, and it is
unnecessary for users to set it again.
Nozzle Mode --- two modes are available, it can be assigned as close-
loop or open-loop.
Channel 1 --- select or deselect
Channel 2 --- select or deselect
Channel 3 --- select or deselect
Channel 4 --- select or deselect
Channel 5 --- select or deselect
Oil Temperature Alarm --- If oil temperature alarm is selected: when the
upper/lower limit of oil temperature has been set, there is no alarm if oil
temperature is within the specification and alarm occurs if it is out of
specification.
SIJECT 15/16 Operation Manual
Fig 3-29
Service screen 2.3 – temperature setting
SIJECT OP15B Screens
to enter service screen 2 --
so as to enter
3-35