SIJECT OP15B Screens
Fast mold open (MldOpn 2) -set the position, pressure and flow of fast
mold open.
Slow mold open (MldOpn 3) -set the position, pressure and flow of
slow mold open.
Mold open tolorence (MldOpnTol) -set the allowed tolorence of mold
open end position. When mold is within this tolorence, then the system
will consider the mold is opened to the end.
Mold position (MldPos) - display the actual position of the mold.
Press
key to close the mold manually,and press
key to
open the mold manually.