Kollmorgen
3
Handling
3.1
Transport
l
l
l
l
l
NOTICE
The servo amplifiers contain electrostatically sensitive components, that can be damaged
by incorrect handling. Discharge yourself before touching the servo amplifier. Avoid con-
tact with highly insulating materials, such as artificial fabrics and plastic films. Place the
servo amplifier on a conductive surface.
3.2
Packaging
l
l
l
3.3
Storage
l
l
l
l
l
S748-S772 Instructions Manual
Transport by qualified personnel in the manufacturer's original recyclable packaging
Avoid shocks while transporting
Transport temperature:
Transport humidity:
If the packaging is damaged, check the unit for visible damage. In such an event, in-
form the shipper and the manufacturer.
Recyclable cardboard with inserts
Dimensions:
390 x 600 x 400 mm
Labeling:
name plate on outside of box
Storage only in the manufacturer's original recyclable packaging
Max. stacking height:
Storage temperature:
Storage humidity:
Storage duration:
Less than 1 year: without restriction.
More than 1 year: capacitors must be re-formed before setting up and operating the
servo amplifier. To do this, remove all electrical connections and apply single-phase
230V AC for about 30 minutes to the terminals L1 / L2.
11/2018
-25 to +70°C, max. rate of change 20K / hour,
class 2K3 acc. to EN61800-2, EN 60721-3-1
max. 95% relative humidity, no condensation,
class 2K3 acc. to EN61800-2, EN 60721-3-1
3 cartons
-25 to +55°C, max. rate of change 20K / hour,
class 1K4 acc. to EN61800-2, EN 60721-3-1
5 ... 95% relative humidity, no condensation,
class 1K3 acc. to EN61800-2, EN 60721-3-1
Handling