Factory Settings - Danfoss VLT 8000 AQUA series Operating Instructions Manual

Hide thumbs Also See for VLT 8000 AQUA series:
Table of Contents

Advertisement

Factory settings

PNU
Parameter
#
description
001
Language
002
Active Setup
003
Copying of Setup
004
LCP copy
005
Max value of user-defined readout
006
Unit for user-defined readout
007
Big display readout
Small display readout 1.1
008
009
Small display readout 1.2
010
Small display readout 1.3
011
Unit of local reference
012
Hand start on LCP
013
OFF/STOP on LCP
014
Auto start on LCP
015
Reset on LCP
016
Lock for data change
017
Operating state at power-up,
local control
100
Configuration
101
Torque characteristics
102
Motor power P
M,N
103
Motor voltage, U
M,N
104
Motor frequence, f
M,N
Motor current, I
105
M,N
106
Rated motor speed, n
107
Automatic motor adaptation,AMA
VT start voltage
108
109
Resonance dampening
110
High brake-away torque
111
Start delay
112
Motor preheater
113
Motor preheater DC current
114
DC braking current
115
DC braking time
116
DC brake cut-in frequency
118
Motor power factor
117
Motor thermal protection
119
Load compensation at low speed
120
Load compensation at high speed
121
Slip compensation
122
Slip compensation time constant
Stator resistance
123
124
Stator reactance
) Global factory setting different from North American factory setting.
196
Factory setting
English
Setup 1
No copying
No copying
100.00
No unit
Frequency, % of max.
Reference, Unit
Motor current, A
Power, HP
Hz
Enable
Enable
Enable
Enable
Not locked
Auto restart
Open loop
Automatic Energy
Optimisation
Depends on the unit
Depends on the unit
60 Hz/
50 Hz
Depends on the unit
Depends on
M,N
par. 102 Motor power
Optimisation disable
Depends on par. 103
100 %
0.0 sec.
0.0 sec.
Disable
50 %
50 %
10 sec.
OFF
0.75
ETR trip 1
100 %
100 %
100 %
0.50 sec.
Depends on the choice
of motor
Depends on the choice
of motor
®
VLT
8000 AQUA
Range
Changes
during
operation
Yes
Yes
No
No
0 - 999.999,99
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
1.1-400 kW
No
(1.5-600 HP
208/480/575 V
No
24-120 Hz
No
0.01 - I
No
VLT,MAX
100-60000 rpm
No
No
0.0 - par. 103
Yes
0 - 500 %
Yes
0.0 - 0.5 sec.
Yes
0.0 - 120.0 sec.
Yes
Yes
0 - 100 %
Yes
0 - 100 %
Yes
0.0 - 60.0 sec.
Yes
0.0-par. 202
Yes
0.50-0.99
No
Yes
0 - 300 %
Yes
0 - 300 %
Yes
-500 - 500 %
Yes
0.05 - 5.00 sec.
Yes
No
No
MG.83.A2.02 - VLT is a registered Danfoss trademark
4-setup
Con-
Data
version
type
index
No
0
5
No
0
5
No
0
5
No
0
5
Yes
-2
4
Yes
0
5
Yes
0
5
Yes
0
5
Yes
0
5
Yes
0
5
Yes
0
5
Yes
0
5
Yes
0
5
Yes
0
5
Yes
0
5
Yes
0
5
Yes
0
5
Yes
0
5
Yes
0
5
Yes
1
6
Yes
0
6
Yes
0
6
Yes
-2
7
Yes
0
6
No
0
5
Yes
-1
6
Yes
0
6
Yes
-1
5
Yes
-1
6
Yes
0
5
Yes
0
6
Yes
0
6
Yes
-1
6
Yes
-1
6
Yes
0
6
Yes
0
5
Yes
0
6
Yes
0
6
Yes
0
3
Yes
- 2
6
Yes
- 4
7
Yes
- 2
7

Hide quick links: