Factory settings
PNU
Parameter
#
description
300 Terminal 16 Digital input
301 Terminal 17 Digital input
302 Terminal 18 Digital input
303 Terminal 19 Digital input
304 Terminal 27 Digital input
305 Terminal 29 Digital input
306 Terminal 32 Digital input
307 Terminal 33 Digital input
308 Terminal 53, analog input voltage
309 Terminal 53, min. scaling
310 Terminal 53, max. scaling
311 Terminal 54, analog input voltage
312 Terminal 54, min. scaling
313 Terminal 54, max. scaling
314 Terminal 60, analog input voltage
315 Terminal 60, min. scaling
316 Terminal 60, max. scaling
317 Time out
318 Function after time out
319 Terminal 42, output
320 Terminal 42, output
pulse scaling
321 Terminal 42, output
322 Terminal 45, output,
pulse scaling
323 Relay 1, output function
324 Relay 01, ON delay
325 Relay 01, OFF delay
326 Relay 2, output function
327 Pulse reference,
max frequency
328 Pulse feedback, max. frequency
364 Terminal 42, bus control
365 Terminal 45, bus control
) Coasting stop, inverse is global factory setting different from North American factory setting.
Changes during operation:
"Yes" means that the parameter can be changed,
while the frequency converter is in operation. "No"
means that the frequency converter must be stopped
before a change can be made.
4-Setup:
"Yes" means that the parameter can be programmed
individually in each of the four setups, i.e. the
same para-meter can have four different data
values. "No" means that the data value will be
the same in all four setups.
Conversion index:
This number refers to a conversion figure to be
used when writing or reading to or from a frequency
converter by means of serial communication.
MG.83.A2.02 - VLT is a registered Danfoss trademark
Factory setting
Range
Reset
No operation
Start
Reversing
Safety interlock/
Coasting stop,
inverse
Jog
No operation
No operation
No operation
0.0 V
0.0 - 10.0 V
10.0 V
0.0 - 10.0 V
No operation
0.0 V
0.0 - 10.0 V
10.0 V
0.0 - 10.0 V
Reference
4.0 mA
0.0 - 20.0 mA
20.0 mA
0.0 - 20.0 mA
10 sec.
1 - 99 sec.
Off
⇒4-20 mA
0 - I
MAX
⇒0-20 mA
0 - f
MAX
5000 Hz
1 - 32000 Hz
No alarm
0.00 sec.
0 - 600 sec.
2.00 sec.
0 - 600 sec.
Running
5000 Hz
Depends on
input terminal
25000 Hz
0 - 65000 Hz
0
0.0 - 100 %
0
0.0 - 100 %
Conversion index
Data type:
Data type shows the type and length of the
telegram.
®
VLT
8000 AQUA
Changes
4-setup
during
operation
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Conversion factor
74
2
1
0
-1
-2
-3
-4
Data type
3
4
5
6
7
9
Conver-
Data
sion
type
index
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
-1
5
-1
5
0
5
-1
5
-1
5
0
5
-4
5
-4
5
0
5
0
5
0
5
0
6
0
5
0
6
0
5
0
6
0
6
0
5
0
6
0
6
-1
6
-1
6
0.1
100
10
1
0.1
0.01
0.001
0.0001
Description
Integer 16
Integer 32
Unsigned 8
Unsigned 16
Unsigned 32
Text string
199

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents