Factory settings
PNU
Parameter
#
description
400 Reset function
401 Automatic restart time
402 Flying start
403 Sleep mode timer
404 Sleep frequency
405 Wake up frequency
406 Boost setpoint
407 Switching frequency
408 Interference reduction
method
409 Function in case of no
load
410 Function at mains failure
411 Function at overtempera-
ture
412 Trip delay overcurr ent,
I
LIM
413 Minimum feedback, FB
414 Maximum feedback,
FB
MAX
415 Units relating to closed
loop
416 Feedback conversion
417 Feedback calculation
418 Setpoint 1
419 Setpoint 2
420 PID normal/inverse
control
421 PID anti windup
422 PID start-up frequency
423 PID proportional gain
424 PID start-up frequency
425 PID differentiation time
426 PID differentiator gain
limit
427 PID lowpass filter time
433 Motor alternation time
434 Motor alteration function
463 Enhanced sleep mode
timer
464 Wakeup pressure
465 Pump min freq
466 Pump max freq
467 NF power at min freq
468 NF power at max freq
469 No/low flow power
compensation
470 Dry run timeout
471 Dry run interlock timer
483 Dynamic DC link
compensation
) Global factory setting different from North
American factory setting
200
Factory setting
Infinate Automatic
10 sec.
0 - 1800 sec.
Enable
Off
0 Hz
f
MIN
60 Hz/
50 Hz
Par. 404 - f
100%
Depends on the
1.5 - 14.0 kHz
unit
ASFM
Warning
Trip
Trip
60 sec
0.000
-999,999.999 -
MIN
100.000
FB
MIN
%
Linear
Maximum
0.000
FB
0.000
FB
Normal
On
0 Hz
0.01
Off
0.01 - 9999.00
Off
0.0 (Off) - 10.00 sec.
5.0
0.01
0 (OFF)
Ramp
0
0
Ref
20
50
0
0
1.2
30 sec.
30 min.
On
VLT
Range
Changes
during
operation
Yes
Yes
Yes
0 - 300 sec.
Yes
- Par. 405
Yes
Yes
MAX
1 - 200 %
Yes
Yes
Yes
Yes
Yes
Yes
0 - 60 sec.
Yes
Yes
FB
MIN
- 999,999.999
Yes
Yes
Yes
Yes
- FB
Yes
MIN
MAX
- FB
Yes
MIN
MAX
Yes
Yes
f
- f
Yes
MIN
MAX
0.00 - 10.00
Yes
Yes
s. (Off)
Yes
5.0 - 50.0
Yes
0.01 - 10.00
Yes
0 - 999 hrs
Yes
Ramp/Coast
Yes
0-9999
Yes
- Setpoint 1
Yes
MIN
f
- f
Yes
MIN
MAX
f
- f
Yes
MIN
MAX
0-16000 W
Yes
0-16000 W
Yes
0.01-9.99
Yes
5-30 sec.
Yes
0.5-60 min.
Yes
No
MG.83.A2.02 - VLT is a registered Danfoss trademark
®
8000 AQUA
4-setup
Conver-
Data
sion
type
index
Yes
0
Yes
0
Yes
-1
Yes
0
Yes
-1
Yes
-1
Yes
0
Yes
2
Yes
0
Yes
0
Yes
0
Yes
0
Yes
0
Yes
-3
Yes
-3
Yes
-1
Yes
0
Yes
0
Yes
-3
Yes
-3
Yes
0
Yes
0
Yes
-1
Yes
-2
Yes
-2
Yes
-2
Yes
-1
Yes
-2
Yes
0
Yes
0
Yes
0
Yes
-3
Yes
-1
Yes
-1
Yes
0
Yes
0
Yes
-2
Yes
0
Yes
-1
No
0
5
6
5
6
6
6
6
5
5
5
5
5
5
4
4
5
5
5
4
4
5
5
6
6
7
6
6
6
6
6
6
4
6
6
7
7
6
5
6
5