Check Every 140 Hours (Once a Week)
Nozzle
1E4C-402E
1B4C-406P
Page 1-28
5.
Remove the nozzle.
∗ Remove 2 bolts on the nozzle and remove it
from the vacuum component. (See the left
figure.)
6.
Clean the nozzle.
∗ Clean it with a cloth soaked with IPA or etha-
nol, or wash it.
∗ After that, dry it before setting.
7.
Install the nozzle after cleaning.
8.
Install the paper tube.
∗ Install the paper tube to the unit at step 4, in
the reverse order.
∗ Insert the paper tube to the projection of the
hinge of the cleaning unit.
9.
Replace the cleaning unit to the in-
side of the main body.
10.
Close the front and center safety
covers.
1E4C-E-MMA01-A06-00