11.2.
Environmental conditions
11.2.1.
DLT-V72 without integrated UPS
Operating temperature
Storage temperature
Relative humidity
Mechanical vibration
and shock resistance
IP protection class
11.2.2.
DLT-V72 with integrated UPS (optional)
The environmental conditions are described in the following chapter:
12.1 Integrated UPS (optional)
60 / 94
-30 to +50 °C
Specification according to EN 60068-2-1/2
-30 to +65 °C
Specification according to EN 60068-2-1/2
10% to 90% at 40 °C relative humidity
Noncondensing
Specification according to EN 60068-2-3
Class 5M3 according to EN 60721-3-5
US Highway Truck according to MIL-STD 810F
IP66 for DLT-V7210 and DLT-V7212
IP65 for DLT-V7210K
DLT-V72 Series Manual V2.00
Technical data
Advantech-DLoG
Need help?
Do you have a question about the DLT-V72 Series and is the answer not in the manual?
Questions and answers