Comtech EF Data PCB-4000A Installation And Operation Manual page 61

1 plus 1 phase combiner
Table of Contents

Advertisement

Command
Command
Parameter
(Instruction
Valid for
Type
Code and
PCB or
SSPA
qualifier)
Summary
N/A
N/A
Fault Status
Remote
SPA=
PCB
Address
Set RTC Time TIM=
ALL
Retrieve
N/A
N/A
Number of
unread
Stored Alarms
Initialize
IAP=
ALL
Stored Alarms
Pointer
Remote State LRS=
PCB
SNMP Read
RCM=
PCB
Community
String
Serial Remote Control
Arguments for
Description of Arguments
Command or
(Note that all arguments are ASCII numeric codes – i.e.,
Response to
ASCII codes between 48 and 57)
Query
1 byte,
Query only.
value of 0,1
Used to Query the status of the Summary Fault Relay.
Example: SFS=0 where:
0 = OK
1 = FT
4 bytes,
Command or Query.
numerical
Set Physical Address-between 0001 to 9999.
Resolution 0001
Example: SPA=0412
Default: 1
6 bytes,
Command or Query.
numerical
A command in the form hhmmss, indicating the time from
midnight, where hh = hours, between 00 and 23; mm =
minutes, between 00 and 59, and ss = seconds, between 00
and 59
Example: TIM=231259 would be 23 hours, 12 minutes and 59
seconds past midnight.
2 bytes,
Query only.
numerical
Returns the number of Stored Events which remain unread, in
the form xx.
Example reply: TNA=18
None
Command only.
Resets internal pointer to allow LNA? Query to start at the
beginning of the stored alarms log.
1 byte, value of
Command or Query.
1 or 3
Used set the user's Remote state in the form x, where:
1=Serial Remote (RS-232)
3=Ethernet Remote
Example: LRS=1 (selects Serial Remote)
Up to 20
Command or Query.
characters, no
Sets or returns the SNMP Read Community string.
spaces
Example: RCM=public
Notes: Empty string is not allowed.
Response to
Command
(Target to
Controller)
N/A
SPA=
SPA?
TIM =
TIM?
TIM *
N/A
IAP=
IAP?
IAP*
LRS
LRS?
LRS*
LRS#
RCM=
RCM?
RCM#
5–13
PCB-4000A 1+1 Phase Combiner
Revision 2
Query
Response to
Query Valid
Query
(Instruction
for PCB or
Code and
(Target to
SSPA
qualifier)
Controller)
SFS?
SSPA
SFS=x
(see
Description of
Arguments for
details)
SPA?
PCB
SPA=x
(see
Description of
Arguments for
details)
TIM?
ALL
TIM=xx
(see
Description of
Arguments for
details)
TNA?
SSPA
TNA=xx
(see
Description of
Arguments for
details)
N/A
N/A
N/A
LRS?
PCB
LRS=x
(see
Description of
Arguments)
RCM?
PCB
RCM=x...x
(see
Description of
Arguments)
MN-PCB-4000A

Advertisement

Table of Contents
loading

Table of Contents