Comtech EF Data PCB-4000A Installation And Operation Manual page 58

1 plus 1 phase combiner
Table of Contents

Advertisement

Command
Command
Parameter
(Instruction
Valid for
Type
Code and
PCB or
SSPA
qualifier)
Concise
N/A
N/A
Utility Status
Set
DAT=
ALL
RTC(Real-
Time-Clock)
Date
Retreive
N/A
N/A
Firmware
Number
Retrieve next
N/A
N/A
5 unread
Stored Alarms
Mute State
MUT=
PCB
Serial Remote Control
Arguments for
Description of Arguments
Command or
(Note that all arguments are ASCII numeric codes – i.e.,
Response to
ASCII codes between 48 and 57)
Query
11 bytes
Query only.
alphanumeric
Used to Query the Maintenance status of the unit, response is
comma delimited.
Example: CUS=aaaa,bbbb'cr''lf' where:
aaaa = Remote Unit Address
bbbb = Remote Baud Rate
6 bytes,
Command or Query.
numerical
A command in the form mmddyy, where; dd = day of the
month, between 01 and 31, mm = month of the year, between
01 and 12 and yy = year, between 00 and 99 (2000 to 2099)
Example: DAT=042503 would be April 24, 2003
32 bytes
Query only.
Gets the Firmware Numbers of the unit.
Example: FRW='cr'
BULK=FW-0021045'cr'
MnC =FW-0021046'cr''lf'
145 bytes
Query only.
The unit returns the oldest 5 Stored Events which have not yet
been read over the remote control.
Reply format: Sub-body{CR}Sub-body{CR}Sub-
body{CR}Sub-body{CR}Sub-body, where Sub-body=
YYYYYYYYYY ZZ mmddyy hhmmss, where:
YYYYYYYYYY being the fault description.
ZZ being the alarm type.
FT = Fault
OK = Clear
IF = Information
If there are no new events, the unit will reply with LNA*
1 byte,
Command or Query.
value of 0,1
Mute the SSPAs, where:
0 = Disabled,
1 = Enabled
2 = Inhibit asserted (Query only)
Example: MUT=1
Response to
Command
(Target to
Controller)
N/A
DAT=
DAT?
DAT*
N/A
N/A
MUT=
MUT?
MUT*
5–10
PCB-4000A 1+1 Phase Combiner
Revision 2
Query
Response to
Query Valid
Query
(Instruction
for PCB or
Code and
(Target to
SSPA
qualifier)
Controller)
CUS?
ALL
CUS=x....x
(Check
(see
SSPA
Description of
manual for
Arguments for
arguments
details)
returned
from SSPA)
DAT?
ALL
DAT=xx
(see
Description of
Arguments for
details)
FRW?
ALL
FRW= x....x
(see
Description of
Arguments for
details)
LNA?
SSPA
LNA=YY..ss
(see
Description of
Arguments for
details)
MUT?
ALL
MUT=x
(see
Description of
Arguments for
details)
MN-PCB-4000A

Advertisement

Table of Contents
loading

Table of Contents