Comtech EF Data PCB-4000A Installation And Operation Manual page 60

1 plus 1 phase combiner
Table of Contents

Advertisement

Command
Command
Parameter
(Instruction
Valid for
Type
Code and
PCB or
SSPA
qualifier)
Redundancy
RED=
PCB
/Phase
Combine
Mode
Retrieve
N/A
N/A
Equipment
Type
Retrieve
N/A
N/A
Maintenance
Status
Serial
N/A
PCB
Number
Retrieve
N/A
N/A
Utility Status
Remote Baud
SBR=
PCB
Rate
Serial Remote Control
Arguments for
Description of Arguments
Command or
(Note that all arguments are ASCII numeric codes – i.e.,
Response to
ASCII codes between 48 and 57)
Query
1 byte,
Command or Query.
value of 0, 1,2,3
Set the redundancy/phase combine mode.
0 = Off
1 = 1:1 Phase combined
2 = reserved
3 = reserved
4 = reserved
35 bytes,
Query only.
alphanumeric
The unit returns a string indicating the Model Number and the
value of internal software revision installed.
Example: PCB-4000A Phase Combiner Ver: 1.1.1
42 bytes,
Query only.
alphanumeric
Used to Query the maintenance status of the unit.
P24VT=23.5'cr'
P05VT=4.8'cr'
P03VT=3.3'cr'
P01VT=1.5'cr''lf'
9 bytes,
Query only.
numerical
Used to Query the units 9 digit serial number.
000000000 to
Slave returns its S/N, in the form xxxxxxxxx.
999999999
Example: RSN=000000165
17 bytes
Query only.
alphanumeric
Used to Query the utility status of the unit
Example: RUS='cr'
ADR=0001'cr'
BDR=9600'cr''lf'
4 bytes
Command or Query.
Set remote baud rate as follows:
9600 = 9600 baud
19K2 = 19200 baud
Response to
Command
(Target to
Controller)
RED=
RED?
N/A
N/A
N/A
N/A
SBR=
SBR?
SBR#
5–12
PCB-4000A 1+1 Phase Combiner
Revision 2
Query
Response to
Query Valid
Query
(Instruction
for PCB or
Code and
(Target to
SSPA
qualifier)
Controller)
RED?
PCB
RED=x
(see
Description of
Arguments for
details)
RET?
ALL
RET=x....x
(see
Description of
Arguments for
details)
RMS?
ALL
RMS=x....x
(Check
(see
SSPA
Description of
manual for
Arguments for
arguments
details)
returned
from SSPA)
RSN?
ALL
RSN=xxxxxxxx
x
(see
Description of
Arguments for
details)
RUS?
ALL
RUS=x....x
(Check
(see
SSPA
Description of
manual for
Arguments for
arguments
details)
returned
from SSPA)
SBR?
PCB
SBR=xx
(see
Description of
Arguments for
details)
MN-PCB-4000A

Advertisement

Table of Contents
loading

Table of Contents