Upgrade Hw-Module Fpd Command Output: Example - Cisco ASR 9000 Series User Configuration Manual

Aggregation services router
Hide thumbs Also See for ASR 9000 Series:
Table of Contents

Advertisement

Upgrading FPD

upgrade hw-module fpd Command Output: Example

Use the upgrade hw-module fpd command to upgrade the FPD image on a SPA, SIP or line card.
RP/0/RSP0/CPU0:router# admin
RP/0/RSP0/CPU0:router(admin)# upgrade hw-module fpd fpga location 0/1/cpu0
Mon Jan 12 05:44:37.611 PST
% RELOAD REMINDER:
normal
- If automatic reload operation is desired after the upgrade, please use
- The output of "show hw-module fpd location" command will not display
Continue? [confirm] y
Starting the upgrade/download of following FPD:
=========== ==== ======= ======= =========== =========
Location
=========== ==== ======= ======= =========== =========
0/1/CPU0
------------------------------------------------------
LC/0/1/CPU0:Jan 12 05:44:43.700 : lc_fpd_upgrade[192]: %PLATFORM-UPGRADE_FPD-6-START :
Starting to upgrade fpga subtype image from 0.4 to 0.4 for for this card
0/1/CPU0
SP/0/1/SP:Jan 12 05:44:41.150 : upgrade_daemon[280]: programming...with file
/net/node0_RP1_CPU0/disk0:/asr9k-fpd-3.9.0.25I/fpd/ucode/fpga_jacket_hw80_sw0.4.xsvf
LC/0/1/CPU0:Jan 12 05:44:42.990 : fabricq_mgr[152]: EES:Internal clock detect IDLE
period(-106461) more than threshold(1200000)
LC/0/1/CPU0:Jan 12 05:44:42.990 : ingressq[179]: EES:Internal clock detect IDLE
period(-106461) more than threshold(1200000)
LC/0/1/CPU0:Jan 12 05:45:09.240 : fabricq_mgr[152]: EES:Internal clock detect IDLE
period(-105945) more than threshold(1200000)
LC/0/1/CPU0:Jan 12 05:45:09.241 : ingressq[179]: EES:Internal clock detect IDLE
period(-105944) more than threshold(1200000)
SP/0/1/SP:Jan 12 05:45:16.020 : upgrade_daemon[280]: ...programming...
SP/0/1/SP:Jan 12 05:45:16.034 : upgrade_daemon[280]: ...it will take a while...
SP/0/1/SP:Jan 12 05:45:16.053 : upgrade_daemon[280]: ...it will take a while...
SP/0/1/SP:Jan 12 05:47:42.967 : upgrade_daemon[280]: ...programming...
SP/0/1/SP:Jan 12 05:47:42.981 : upgrade_daemon[280]: ...it will take a while...
% SLC/0/1/CPU0:Jan 12 05:48:08.737 : lc_fpd_upgrade[192]: %PLATFORM-UPGRADE_FPD-6-PASSED :
Successfully upgrade fpga subtype image for for this card
show platform Command Output: Example
Use the show platform command to verify that the SPA is up and running.
RP/0/RSP0/CPU0:router# show platform
Sat Jul 25 12:26:38.905 DST
Node
-----------------------------------------------------------------------------
0/RSP0/CPU0
0/FT0/SP
0/FT1/SP
- The upgrade operation of the target module will not interrupt its
operation. However, for the changes to take effect, the target module
will need to be manually reloaded after the upgrade operation. This can
be accomplished with the use of "hw-module <target> reload" command.
the "reload" option at the end of the upgrade command.
correct version information after the upgrade if the target module is
not reloaded.
Type Subtype Upg/Dng
lc
fpga
upg
Type
A9K-RSP-4G(Active)
FAN TRAY
FAN TRAY
Cisco ASR 9000 Series Aggregation Services Router System Management Configuration Guide, Release 5.1.x
upgrade hw-module fpd Command Output: Example
Current
Upg/Dng
Version
Version
0.40
0.40
State
IOS XR RUN
READY
READY
on location
on location 0/1/CPU0
Config State
PWR,NSHUT,MON
187

Advertisement