Troubleshooting; Troubleshooting Guide - Henny Penny Evolution Elite EEE-154 Operator's Manual

Wendy's reduced oil capacity open fryers, full vat – electric
Hide thumbs Also See for Evolution Elite EEE-154:
Table of Contents

Advertisement

7-1. TROUBLE SHOOTING GUIDE
Problem Cause
POWER switch ON but
fryer completely inoperative
Oil will not heat but
lights are on
Control error code "E-10"
Vat is under-fi lled
7-1
SECTION 7. TROUBLESHOOTING
• Open circuit
• All power cords not
not plugged-in
• Open high limit circuit
• BIB is low or empty
• BIB oil line is clogged
or collapsed
• Filter pan needs
cleaned
Model EEE-153, 154
Correction
• Plug fryer in
• Check breaker or fuse at supply box
• (Non-US/some Int'l. locations only)
Breakers in fryer tripped-open left
door and reset breaker on fryer; See
below
• Unit has 2 power cords; make sure
both are plugged-in
• Let unit cool down (15-20 minutes),
reset the high limit using the high limit
tool on the inside of the LH door and
gently pushing it into the hole in the
heating element hinge; if high limit
does not reset, high limit must be
replaced
• Fill the BIB
• Check BIB line
• Clean fi lter pan and change paper or
pad
811