SmartRunner Matcher*
Operation
Index
Parameter name
0xCD Tolerance object
0x29
Tolerance X
0x38
Tolerance Z
0x54
Set/Get Profile
name
0x55
Get Profile index
0x56
Set/Get Profile
information
Save settings
01 F3 10 E2
Saves the current settings in the flash memory
Reset
01 F3 02 F0
Returns to default settings.
Load settings
01 F3 00 F2
The current order and the settings are reloaded.
Switch to Profile
02 F3 03 XX XOR
XX = profile number (1...32)
Example: profile number [2]: 02 F3 03 02 F0
Trigger Laser
01 64 01 XOR
Triggers an image capture with evaluation
Trigger LED
01 64 02 XOR
Triggers the LEDs
1.Only with VLM350-F280-R4-1001 and VLM350-F280-R4-1101
Data
Length/bytes Read/write Description
1
4
4
0 – 32
1
0
1
255
1
1
R/W
Envelope around the taught-in profile
in 0.1 mm increments. The envelope
is the basis for the quality parameters
R/W
Maximum permissible deviation of
the object in the X direction relative to
the taught-in position in mm
R/W
Maximum permissible deviation of
the object in the Z direction relative to
the taught-in position in mm
R/W
Write/read a name for the current
profile.
R
Returns the index of the currently
active profile.
R/W
Set/retrieve profile information.
43
Need help?
Do you have a question about the SmartRunner Matcher and is the answer not in the manual?