Ikegami HDK-55 Operation Manual page 146

High definition camera system
Hide thumbs Also See for HDK-55:
Table of Contents

Advertisement

7.3 External Connections
Pin No.
Name
IRIS FOLLOW SE
43
ZOOM FOLLOW SE
44
N . C
45
N . C
46
N . C
47
N . C
48
N . C
49
N . C
50
130
Function
LENS IRIS control output in SE operation
F 2.8
: 6.2 V± 0.05 V
(6.2 V± 0.1 V)
F 16
: 3.4 V± 0.05 V
(3.4 V± 0.1 V)
CLOSE : 2.5 V± 0.2 V
(2.1 V to 2.9 V)
Zin = 100 kΩ± 2% (100 kΩ or more)
Lens zoom control output in SE operation
WIDE : 2.0 V± 0.05 V
(2.0 V± 0.2 V)
TELE : 7.0 V± 0.05 V
(7.0 V± 0.2 V)
Zin = 100 kΩ± 2% (10 kΩ or more)
Zout = 1 kΩ± 10% (1 kΩ or less)
(Unusable)
(Unusable)
(Unusable)
(Unusable)
(Unusable)
(Unusable)
HDK-55 1206 VER1 (U)