8 CC-Link Data Table
Device
External Baseblock
RY9
Command
RYA
External Fault
RYB
Reserved
RYC
Monitor Reference
RYD, E
Reserved
Command Code Execute
RYF
Request
RY10
Terminals M1-M2 Function
Terminals P1-PC
RY11
Function
Terminals P2-PC
RY12
Function
RY13
Reserved
RY14
Terminal S1 Function
RY15
Terminal S2 Function
RY17 Enabled/Disabled
RY16
Selection
Terminal MA/MB-MC
RY17
Function
RY18, 19
Reserved
RY1A
Fault Reset
RY1B
Reserved
to 1F
<1> Terminals will differ depending on the model of the drive. Refer to
Model of the Drive on page 46
Note: Although RYF is triggered by the rising edge of the signal, they are otherwise enabled depending
on the value that is input.
42
Name
ON: Motor coasts to stop.
OFF: Energy-saving unit will
begin operating as soon as a Run
command is given.
ON: External Fault Input (EF0)
ON: Monitor data specified in the
monitor code is set to remote
register RW
Request to execute the command
code.
Multi-Function Relay Output 1
(terminal M1-M2)
Multi-Function Photocoupler
Relay Output 1 (terminal P1-PC)
<1>
Multi-Function Photocoupler
Relay Output 2 (terminal P2-PC)
<1>
Multi-Function Input: H1-01
Multi-Function Input: H1-02
Fault Contact Output (terminal
MA/MB-MC)
Resets an energy-saving unit fault.
for information on terminals.
YASKAWA ELECTRIC TOBP C730600 83C YASKAWA AC Drive Option SI-C3 Installation Manual
Description
.
R0
Terminals that Change depending on the
Default
When switching between monitors
using RYC (Monitor Reference),
RYC needs to be turned off and
then back on again after the
monitor code has been changed.
Triggered by the rising edge of the
signal.
Function is disabled when for the
Run Command (H1-01 = 4B).
Function is disabled when for the
Stop Command (H1-02 = 4C).