Figure 2: Typical Overload Characteristics In The Lower Output Frequencies (Ol2) Example - KEB COMBIVERT F6 Instructions For Use Manual

Hide thumbs Also See for COMBIVERT F6:
Table of Contents

Advertisement

UNIT DATA OF THe 400V UNITS
The following characteristics indicate the permissible maximum current for the output
frequency values 0 Hz, 3 Hz, 6 Hz, 10 Hz 25 Hz and 50 Hz. If the switching frequencies
are different, there is an interpolation between the characteristics. Unit size 19 is repre-
sented exemplary.
240
220
200
180
160
140
120
100
80
60
40
20
0
0
5
10
Legend
Overcurrent I
OC
Software current limit I
Switching frequency 2 kHz
Switching frequency 4 kHz
Switching frequency 8 kHz
Switching frequency 12 kHz
Switching frequency 16 kHz
Not available for modulation. Error OC is triggered at 180% overload.
Figure 2:
Typical overload characteristics in the lower output frequencies (OL2) Example. Unit size 19
32
15
20
25
Output frequency in Hz
(the limit can be set with parameter is35)
lim
30
35
40
45
50
55
60