Reduction of Output Current in Accordance with UL

Site altitude above sea level
Maximum surrounding air temperature
3.4.4

Dimensions

Figure 1 – Small Housing
Isolation Sheet 0091999-9035
A clearance distance of min. 9.5mm to the terminal must be observed when
assembling on conductive, grounded surface. The included isolation sheet must be
sub-mounted if the minimum clearance distance above is not given.
AC Voltage Input
DC Voltage Output
Switching Input for DC Side. When terminals are not included, the switch contact must
be wired externally.
See wiring diagram.
12
≤1000m 100% Nominal Current
>1000m -1% Nominal Current per 100m (max. 2000m)
45°C
1.2A output current (nominal current)
60°C
0.9A output current
75°C
0.6A output current
85°C
0.5A output current
Figure 2 – Large Housing
Isolation Sheet 04591999-6038
All dimensions in mm
2021 KEB America, Inc.
©