Humidity Sensor B-530 (Option) - GRAPHTEC midi LOGGER GL220 User Manual

Hide thumbs Also See for midi LOGGER GL220:
Table of Contents

Advertisement

CHAPTER 4 Specifications

Humidity Sensor B-530 (Option)

Allowable temperature range
Allowable humidity range
Relative humidity measurement
accuracy
Method
Relative humidity measurement
accuracy
(5~98%)
Response time
Sensor output
Sensor power
Consumption current
External dimensions
Cable length
List of Options
Logic alarm cable
DC drive cable
Battery pack
Humidity sensor *1
Humidity sensor power box
M3 screws with flat washers (60)
USB memory 2GB
Shunt resistor 250 Ω
T-type thermocouple *2
K-type thermocouple *2
Extra fine K-type thermocouple
(TC200/TD1000), 5 per set
Needle-shape K-type thermo-
couple
Stationery-surface K-type thermo-
couple
L-type stationery-surface K-type
thermocouple
Mini-connector for K-type thermo-
couple (5 per set)
Mini-connector for K-type thermo-
couple (2 per set)
Mini-connector for T-type thermo-
couple (5 per set)
Mini-connector for T-type thermo-
couple (2 per set)
*1: Allowable temperature range: -25 to +80°C
*2: Sold only in Japan
4-8
Item
-25 to +80°C
0 to 100% RH
±3% RH (5 to 98% RH at 25°C)
Capacitance method
15 s (90% response when membrane filter installed)
0 to 1 VDC
+5 to +16 VDC
+Approx. 4 mA
φ14 mm x 80 mm (excluding cable)
3 m
Item
Option No.
B-513
B-514
B-517
B-530
B-542
B-543
B-550
B-551
JSB-7115-5M-T
JSB-7115-5M-K
ST-55K-TC-1.2M Tip wire diameter of 0.127, 0.5 x 0.7 x 200 mm, Relay
RIC-410
RIC-420
RIC-430
RIC-440
RIC-441
RIC-450
RIC-451
Description
Measurement environment
0~10°C
10~20°C
20~30°C
30~40°C
40~50°C
50~60°C
60~70°C
70~80°C
2m, Bare tips
2m, Bare tips
7.4V/2200mAh 17Wh
3 m, with dedicated power connector
For connection with 10 humidity sensors: Built to order
60 per set
2GB
250 Ω, Rated power of 1 W, Maximum service voltage
of 15.8 V, Built to order
5-m length, 5 thermocouples per set, wire diameter of
0.32, 1.0 x 1.6 x 5000 mm
5-m length, 5 thermocouples per set, wire diameter of
0.32, 1.0 x 1.6 x 5000 mm
part 1 m, 5 per set
-100 to 300°C, Class 1, Cord length: 1.1 m
-30 to 400°C, Class 2, Cord length: 1.1 m
-30 to 600°C, Class 2, Cord length: 1.1 m
5 per set, Connectable thermocouple: Wire diameter of
0.65 mm, End terminal: M3Y terminal
2 per set, Connectable thermocouple: Wire diameter of
0.65 mm, End terminal: M3Y terminal
5 per set, Connectable thermocouple: Wire diameter of
0.65 mm, End terminal: M3Y terminal
2 per set, Connectable thermocouple: Wire diameter of
0.65 mm, End terminal: M3Y terminal
Measurement accuracy
±5% RH
±4% RH
±3% RH
±4% RH
±5% RH
±6% RH
±7% RH
±8% RH
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents